Tank Roof Air Raising

Contact Us For Help?

Contact with us through our representative or submit a business inquiry online.

Contact Us

Tank Roof Air Raising

Pneumatic Tank Roof Air Raising Method by FEPCO Egypt

We deliver specialized tank roof air raising services utilizing advanced pneumatic lifting techniques in full compliance with international safety standards. Our expertise ensures precise execution, reduced construction time, and enhanced structural integrity, particularly for large-scale oil storage tank projects.

Key Projects

Strategic Crude Oil Storage Tanks – Agroud, Suez, Egypt

Client: ARESCO  ·  End Client: EGPC
Scope: Execution of tank roof air raising for 4 floating roof storage tanks.
Details: Double deck floating roofs, Diameter: 110 mt, Weight: 1,200 tons each. Completed within ~2 months in compliance with API 650 and HSE standards.
* Part of a strategic national petroleum storage project.

Strategic Crude Oil Storage Tanks – Ras Gharib, Red Sea, Egypt

Client: Petrojet  ·  End Client: EGPC
Scope: Execution of tank roof air raising for 4 floating roof storage tanks.
Details: Double deck floating roofs, Diameter: 110 mt, Weight: 1,200 tons each. Completed within ~2 months in compliance with API 650 and HSE standards.
* Part of a strategic national petroleum storage project.

Fadhili Gas Increment Project – Saudi Arabia COMPLETED

Client: AIC Steel  ·  Main Contractor: Samsung E&A  ·  End Client: Saudi Aramco
Scope: Execution of tank roof air raising for 5 API 650 dome roof storage tanks with external rafters (PKG4).
Details:

  • Condensate Tanks (2) – D46-D-2401A/B: Dia: 47m, Height: 16.6m, Roof Weight: 272 tons. Air-raising pressure: 173 mmH2O, approx. 95 min.
  • Potable Water Tanks (2) – D46-D-2001A/B: Dia: 35m, Height: 15.2m, Roof Weight: 150 tons. Air-raising pressure: 170 mmH2O, approx. 85 min.
  • Sour Water Tank (1) – D42-D-3502: Dia: 27.5m, Height: 9.8m, Roof Weight: 98 tons. Air-raising pressure: 180 mmH2O, approx. 52 min.
All tanks fixed roof with external rafters, executed per API 650 and ARAMCO standards. Average raising speed of 160 mm/min using 2 operating + 2 standby blowers per tank, with an across-tank levelling system and stabilizing cables.

Project Gallery

Fire Water Dome Roof Tank Air Raising - Iraq Project Fadhili Gas Increment Project Saudi Aramco Tank Roof Air Raising Strategic Crude Oil Tanks Execution at Ras Gharib Red Sea Strategic Crude Oil Storage Tanks Agroud Suez Project Heavy Weight Tank Roof Mechanical Air Raising Execution API 650 Compliant Tank Roof Pneumatic Air Raising

Fadhili Gas Increment Project – Photo Gallery

Fadhili Gas Increment Project PKG4 - dome roof tank before air raising FEPCO crew working at the tank rim during roof air raising, Fadhili Saudi Arabia Tank Roof Air Raising operation in progress sign, Fadhili Gas Increment Program PKG-4 Air raising blowers and control units set up beside the tank, Fadhili project Dome roof with external rafters raised to final position, Fadhili Saudi Aramco Condensate Tank B tank roof air raising, Fadhili Gas Increment Project Completed API 650 storage tanks at sunset, Fadhili Gas Increment Project FEPCO site team at Fadhili tank roof air raising project

Project Execution Video




If You Need Any Industrial Solution... We Are Available For You